Get in touch

csa rpvu90 rpv90 solar cable-0

Solar/PV Cable

Home >  Products >  Solar/PV Cable

  • CSA RPVU90 RPV90 Solar Cable
  • CSA RPVU90 RPV90 Solar Cable
  • CSA RPVU90 RPV90 Solar Cable
  • CSA RPVU90 RPV90 Solar Cable
  • CSA RPVU90 RPV90 Solar Cable
  • CSA RPVU90 RPV90 Solar Cable

CSA RPVU90 RPV90 Solar Cable

OVERVIEW

Applications

RPVU90, RPV90 cables may be installed indoors or outdoors, in raceways and conduits, both above and below ground, and may be direct buried. RPVU90 can be used in direct burial installations. It must comply with CE Code Rules 12-012 and 4-004. They are 90ºC, 2 kV rated, and suitable for use in a photovoltaic system.

Type RPVU90 cable is for use on the DC and AC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight.

Type RPV90 cable is for use on the DC and AC side of a photovoltaic system, suitable for installation in dry locations, and may be exposed to sunlight.

RPVU90/RPV90 cables are RoHS Compliant.

 

Standards

• CSA C22.2 No. 38 - Thermoset-Insulated Wires and Cables

• CSA C22.2 No. 271-11

• ASTM B3, B8, B787

cUL File No.: E365883

CSA File No.: 271587

 

Features

Voltage: 

600V/1000V/2000V

Working temperature:

90ºC MAX, -40ºC MIN

Performance:

• Deformation-resistant at high temperatures

• Excellent moisture resistance, exceeds UL 44

• Stable electrical properties over a broad temperature range

• Increased flexibility

• Resistant to crush and compression cuts

• UV/sunlight-resistant

SPECIFICATIONS

DM_20250905095613_001.jpgROHS
DM_20250905084822_001.jpgUV Resistance
DM_20250904092918_001.jpgWorking Temperature 90℃

 

1000V/2000V RPVU90

All dimensions are nominal are nominal and subject to normal manufacturing tolerances.

Size

(AWG/Kcmil)

Conductor

Ins.

Thickness

Approx O.D. Weight/Km

Max. DC

resistanceat 20 C

Nos of

strands(CU)

Nos of

strands(AL)

mm(CU) mm(AL) mm(CU) mm(AL) kgs(CU) kgs(AL) Ω/km(CU) Ω/km(AL)
12 7 / 1.52 / 5.3 / 57.8 / 5.43 /
10 7 / 1.52 / 5.9 / 79.9 / 3.41 /
8 7 / 2.03 / 7.7 / 130.2 / 2.14 /
6 7 7 2.03 2.03 8.6 8.4 165.7 84 1.35 2.210
4 7 7 2.03 2.03 9.8 9.5 246.1 113 0.848 1.390
2 7 7 2.03 2.03 11.3 10.9 366.9 156 0.534 0.875
1/0 19 18 2.41 2.41 14.0 13.3 576.0 238 0.335 0.550
2/0 19 18 2.41 2.41 14.8 14.4 706.1 285 0.266 0.436
3/0 19 19 2.41 2.41 16.4 15.5 876.3 341 0.211 0.346
4/0 19 19 2.41 2.41 17.8 16.9 1,083.4 412 0.167 0.274
250 37 36 2.79 2.79 19.8 18.8 1,293.4 498 0.142 0.232
350 37 36 2.79 2.79 22.4 21.3 1,768.1 657 0.101 0.166
400 37 36 2.79 2.79 23.5 22.3 2,003.5 734 0.0885 0.145
500 37 36 2.79 2.79 25.6 24.3 2,473.2 888 0.0709 0.116
750 61 60 3.18 3.18 31.0 29.3 3,676.8 1,305 0.0472 0.0774

 

2000V RPV90 Aluminium AA8000

All dimensions are nominal are nominal and subject to normal manufacturing tolerances.

Size

(AWG/Kcmil)

Conductor

Ins.

Thickness

Approx

O.D.

Weight/Km

Max. DC

resistanceat 20 C )

Nos of

strands

mm mm kgs Ω/km
6 7 1.78 7.9 74.1 2.210
4 7 1.78 9.0 102.0 1.390
3 7 1.78 9.6 120.5 1.100
2 7 1.78 10.4 143.6 0.875
1 18 2.29 12.2 192.5 0.693
1/0 18 2.29 13.1 228.6 0.550
2/0 18 2.29 14.2 274.0 0.436
3/0 19 2.29 15.3 329.6 0.346
4/0 19 2.29 16.7 398.8 0.274
250 36 2.67 18.5 482.6 0.232
350 36 2.67 21.0 639.1 0.166
400 36 2.67 22.0 715.2 0.145
500 36 2.67 24.0 867.0 0.116
750 60 3.05 29.0 1,271.3 0.0774
1500 91 3.56 41.2 2,452.8 0.0387

STRUCTURE

DM_20250905095518_001.jpg

Aluminum:

• sizes from #6 AWG to 1000 kcmil, stranded

• compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 Class B or ASTM B836

 

Copper:

• sizes from #14 AWG to 1000 kcmil, solid or stranded

• bare, stranded annealed per ASTM B8 Class B compressed

INQUIRY