Usus
RPVU90, RPV90 cables may be installed indoors or outdoors, in raceways and conduits, both above and below ground, and may be direct buried. RPVU90 can be used in direct burial installations. It must comply with CE Code Rules 12-012 and 4-004. They are 90ºC, 2 kV rated, and suitable for use in a photovoltaic system.
Type RPVU90 cable is for use on the DC and AC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight.
Type RPV90 cable is for use on the DC and AC side of a photovoltaic system, suitable for installation in dry locations, and may be exposed to sunlight.
RPVU90/RPV90 cables are RoHS Compliant.
Standards
• CSA C22.2 No. 38 - Thermoset-Insulated Wires and Cables
• CSA C22.2 No. 271-11
• ASTM B3, B8, B787
cUL File No.: E365883
CSA File No.: 271587
Proprietates
V oltage:
600V/1000V/2000V
Temperature opus:
90ºC MAX, -40ºC MIN .
Performantia:
• Deformationi resistentes ad altas temperaturas
• Excellent humiditatis resistentia, excedit UL 44
• Stabilis electrica proprietates super lata temperatus range
• auxit flexibilitate
• Resistentes ad confringere et secare compressione
• UV / solis repugnans
1000V/2000V RPVU90
Omnes dimensiones nominis sunt et subiectae sunt tolerantiis manufacturae communibus.
Magnitudo (AWG/Kcmil) |
Conductor |
Ins. Crassitudo |
Approx O.D. | Pondus/Km |
Max. DC resistentiaad 20 C |
|||||
Nos de strands(CU) |
Nos de strands(AL) |
mm(CU) | mm(AL) | mm(CU) | mm(AL) | kgs(CU) | kgs(AL) | ω/km(CU) | ω/km(AL) | |
12 | 7 | / | 1.52 | / | 5.3 | / | 57.8 | / | 5.43 | / |
10 | 7 | / | 1.52 | / | 5.9 | / | 79.9 | / | 3.41 | / |
8 | 7 | / | 2.03 | / | 7.7 | / | 130.2 | / | 2.14 | / |
6 | 7 | 7 | 2.03 | 2.03 | 8.6 | 8.4 | 165.7 | 84 | 1.35 | 2.210 |
4 | 7 | 7 | 2.03 | 2.03 | 9.8 | 9.5 | 246.1 | 113 | 0.848 | 1.390 |
2 | 7 | 7 | 2.03 | 2.03 | 11.3 | 10.9 | 366.9 | 156 | 0.534 | 0.875 |
1/0 | 19 | 18 | 2.41 | 2.41 | 14.0 | 13.3 | 576.0 | 238 | 0.335 | 0.550 |
2/0 | 19 | 18 | 2.41 | 2.41 | 14.8 | 14.4 | 706.1 | 285 | 0.266 | 0.436 |
3/0 | 19 | 19 | 2.41 | 2.41 | 16.4 | 15.5 | 876.3 | 341 | 0.211 | 0.346 |
4/0 | 19 | 19 | 2.41 | 2.41 | 17.8 | 16.9 | 1,083.4 | 412 | 0.167 | 0.274 |
250 | 37 | 36 | 2.79 | 2.79 | 19.8 | 18.8 | 1,293.4 | 498 | 0.142 | 0.232 |
350 | 37 | 36 | 2.79 | 2.79 | 22.4 | 21.3 | 1,768.1 | 657 | 0.101 | 0.166 |
400 | 37 | 36 | 2.79 | 2.79 | 23.5 | 22.3 | 2,003.5 | 734 | 0.0885 | 0.145 |
500 | 37 | 36 | 2.79 | 2.79 | 25.6 | 24.3 | 2,473.2 | 888 | 0.0709 | 0.116 |
750 | 61 | 60 | 3.18 | 3.18 | 31.0 | 29.3 | 3,676.8 | 1,305 | 0.0472 | 0.0774 |
2000V RPV90 Aluminium AA8000
Omnes dimensiones nominis sunt et subiectae sunt tolerantiis manufacturae communibus.
Magnitudo (AWG/Kcmil) |
Conductor |
Ins. Crassitudo |
Proxime O.D. |
Pondus/Km |
Max. DC resistentiaad 20 C ) |
Nos de strands |
mm | mm | kgs | ω\/km | |
6 | 7 | 1.78 | 7.9 | 74.1 | 2.210 |
4 | 7 | 1.78 | 9.0 | 102.0 | 1.390 |
3 | 7 | 1.78 | 9.6 | 120.5 | 1.100 |
2 | 7 | 1.78 | 10.4 | 143.6 | 0.875 |
1 | 18 | 2.29 | 12.2 | 192.5 | 0.693 |
1/0 | 18 | 2.29 | 13.1 | 228.6 | 0.550 |
2/0 | 18 | 2.29 | 14.2 | 274.0 | 0.436 |
3/0 | 19 | 2.29 | 15.3 | 329.6 | 0.346 |
4/0 | 19 | 2.29 | 16.7 | 398.8 | 0.274 |
250 | 36 | 2.67 | 18.5 | 482.6 | 0.232 |
350 | 36 | 2.67 | 21.0 | 639.1 | 0.166 |
400 | 36 | 2.67 | 22.0 | 715.2 | 0.145 |
500 | 36 | 2.67 | 24.0 | 867.0 | 0.116 |
750 | 60 | 3.05 | 29.0 | 1,271.3 | 0.0774 |
1500 | 91 | 3.56 | 41.2 | 2,452.8 | 0.0387 |
Aluminium:
• magnitudines e #6 AWG ad 1000 kcmil, sectae
• materia conductoris alluminium seriei AA-8000 secta (ACM) secundum ASTM B801 Classis B vel ASTM B836
Cuprum:
• magnitudines e #14 AWG ad 1000 kcmil, solidae vel sectae
• nudae, sectae recedentis secundum ASTM B8 Classis B compressae