OVERVIEW

Usus

RPVU90, RPV90 cables may be installed indoors or outdoors, in raceways and conduits, both above and below ground, and may be direct buried. RPVU90 can be used in direct burial installations. It must comply with CE Code Rules 12-012 and 4-004. They are 90ºC, 2 kV rated, and suitable for use in a photovoltaic system.

Type RPVU90 cable is for use on the DC and AC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight.

Type RPV90 cable is for use on the DC and AC side of a photovoltaic system, suitable for installation in dry locations, and may be exposed to sunlight.

RPVU90/RPV90 cables are RoHS Compliant.

 

Standards

• CSA C22.2 No. 38 - Thermoset-Insulated Wires and Cables

• CSA C22.2 No. 271-11

• ASTM B3, B8, B787

cUL File No.: E365883

CSA File No.: 271587

 

Proprietates

V oltage:

600V/1000V/2000V

Temperature opus:

90ºC MAX, -40ºC MIN .

Performantia:

• Deformationi resistentes ad altas temperaturas

• Excellent humiditatis resistentia, excedit UL 44

• Stabilis electrica proprietates super lata temperatus range

• auxit flexibilitate

• Resistentes ad confringere et secare compressione

• UV / solis repugnans

SPECIFICATIONS

DM_20250905095613_001.jpgROHS
DM_20250905084822_001.jpgUV Resistentia
DM_20250904092918_001.jpgTemperatura Operativa 90℃

 

1000V/2000V RPVU90

Omnes dimensiones nominis sunt et subiectae sunt tolerantiis manufacturae communibus.

Magnitudo

(AWG/Kcmil)

Conductor

Ins.

Crassitudo

Approx O.D. Pondus/Km

Max. DC

resistentiaad 20 C

Nos de

strands(CU)

Nos de

strands(AL)

mm(CU) mm(AL) mm(CU) mm(AL) kgs(CU) kgs(AL) ω/km(CU) ω/km(AL)
12 7 / 1.52 / 5.3 / 57.8 / 5.43 /
10 7 / 1.52 / 5.9 / 79.9 / 3.41 /
8 7 / 2.03 / 7.7 / 130.2 / 2.14 /
6 7 7 2.03 2.03 8.6 8.4 165.7 84 1.35 2.210
4 7 7 2.03 2.03 9.8 9.5 246.1 113 0.848 1.390
2 7 7 2.03 2.03 11.3 10.9 366.9 156 0.534 0.875
1/0 19 18 2.41 2.41 14.0 13.3 576.0 238 0.335 0.550
2/0 19 18 2.41 2.41 14.8 14.4 706.1 285 0.266 0.436
3/0 19 19 2.41 2.41 16.4 15.5 876.3 341 0.211 0.346
4/0 19 19 2.41 2.41 17.8 16.9 1,083.4 412 0.167 0.274
250 37 36 2.79 2.79 19.8 18.8 1,293.4 498 0.142 0.232
350 37 36 2.79 2.79 22.4 21.3 1,768.1 657 0.101 0.166
400 37 36 2.79 2.79 23.5 22.3 2,003.5 734 0.0885 0.145
500 37 36 2.79 2.79 25.6 24.3 2,473.2 888 0.0709 0.116
750 61 60 3.18 3.18 31.0 29.3 3,676.8 1,305 0.0472 0.0774

 

2000V RPV90 Aluminium AA8000

Omnes dimensiones nominis sunt et subiectae sunt tolerantiis manufacturae communibus.

Magnitudo

(AWG/Kcmil)

Conductor

Ins.

Crassitudo

Proxime

O.D.

Pondus/Km

Max. DC

resistentiaad 20 C )

Nos de

strands

mm mm kgs ω\/km
6 7 1.78 7.9 74.1 2.210
4 7 1.78 9.0 102.0 1.390
3 7 1.78 9.6 120.5 1.100
2 7 1.78 10.4 143.6 0.875
1 18 2.29 12.2 192.5 0.693
1/0 18 2.29 13.1 228.6 0.550
2/0 18 2.29 14.2 274.0 0.436
3/0 19 2.29 15.3 329.6 0.346
4/0 19 2.29 16.7 398.8 0.274
250 36 2.67 18.5 482.6 0.232
350 36 2.67 21.0 639.1 0.166
400 36 2.67 22.0 715.2 0.145
500 36 2.67 24.0 867.0 0.116
750 60 3.05 29.0 1,271.3 0.0774
1500 91 3.56 41.2 2,452.8 0.0387

STRUCTURE

DM_20250905095518_001.jpg

Aluminium:

• magnitudines e #6 AWG ad 1000 kcmil, sectae

• materia conductoris alluminium seriei AA-8000 secta (ACM) secundum ASTM B801 Classis B vel ASTM B836

 

Cuprum:

• magnitudines e #14 AWG ad 1000 kcmil, solidae vel sectae

• nudae, sectae recedentis secundum ASTM B8 Classis B compressae